Kingflex Kingflex

China Elastomeric Insulation For the Ultra Low Temperature Systems Supplier, Factory

Kingflex ULT is a flexible, high density and mechanically robust, closed cell cryogenic thermal insulation material based on extruded elastomeric foam.

Product Description

Cryogenic application
Cryogenic system detail
Low temperature pipeline insulation
Key Application Fields
Coal chemical MOT
Low temperature storage tank
FPSO floating production storage oil unloading device
Industrial gas & agricultural chemical plants
Platform pipe
Gas station
Ethylene pipe
LNG
Nitrogen plant

The product has been specially developed for use on the import or export pipelines and process areas of (liquefied natural gas) facilities. It is a part of Cryogenic multi layer configuration, providing low temperature flexibility to the system.

Cryogenic multi layer insulation
Low temp pipe flexibility detail
Pipeline insulation structure
Process area pipe insulation
Thermal insulation layer
Cryogenic insulation application photo
Liquefied natural gas pipeline wrapping
📋 Product Dimensions
Dimension Specifications
Inches mm Size (L * W) ㎡ / Roll
3/4" 20 10 × 1 10
1" 25 8 × 1 8
Main Technical Properties
Main Property Base Material Standard / Test Method
ULT LT
Thermal Conductivity -100°C: 0.028
-165°C: 0.021
0°C: 0.033
-50°C: 0.028
ASTM C177
Density Range 60-80 Kg/m³ 40-60 Kg/m³ ASTM D1622
Recommend Operation Temperature -200°C to 125°C -50°C to 105°C -
Percentage of Close Areas >95% >95% ASTM D2856
Moisture Performance Factor NA < 1.96x10⁻¹¹ g/(m.s.Pa) ASTM E 96
Wet Resistance Factor (μ) NA > 10000 EN12086 / EN13469
Water Vapor Permeability Coefficient NA 0.0039 g/h.m² (25mm thickness) ASTM E 96
PH ≥ 8.0 ≥ 8.0 ASTM C871
Tensile Strength (MPa) -100°C: 0.30
-165°C: 0.25
0°C: 0.15
-50°C: 0.218
ASTM D1623
Compressive Strength (MPa) -100°C: ≤ 0.3 -40°C: ≤ 0.16 ASTM D1621
Cryogenic insulation verification
Cryogenic material test diagram
Frequently Asked Questions (FAQ)
Q What is the primary application for this cryogenic insulation product?
This product is specially designed for low-temperature applications including import/export pipelines and process areas of liquefied natural gas (LNG) facilities, low-temperature storage tanks, ethylene pipes, and platform piping.
Q How does this insulation system improve low-temperature performance?
It is configured as a multi-layer cryogenic insulation structure, which provides the system with excellent flexibility and performance at extremely low operating temperatures.
Q What is the recommended operating temperature range for the ULT and LT base materials?
The recommended operating temperature range for the ULT material is -200°C to 125°C, while the LT material is recommended for operations from -50°C to 105°C.
Q What are the thermal conductivity properties of the ULT material?
According to the ASTM C177 standard, the thermal conductivity values for the ULT base material are 0.028 W/(m·K) at -100°C and 0.021 W/(m·K) at -165°C.
Q What standard size configurations are available for these rolls?
Standard configurations include a 3/4" (20 mm) thickness option sized at 10m × 1m (yielding 10 m² per roll) and a 1" (25 mm) thickness option sized at 8m × 1m (yielding 8 m² per roll).

Related Products