China Kingflex Aluminum Foil-Clad Rubber Foam Sheet Roll Pricelist, Quotes

Kingflex aluminum foil coated nitrile nbr/pvc rubber foam sheet roll.

Product Description

Insulation Roll Sample 1
Insulation Roll Sample 2
Insulation Roll Sample 3
Aluminum foil-clad rubber foam insulation roll has very low thermal conductivity and excellent acoustic insulation—can reduce noise and sound transmitting. The aluminum foil-clad rubber foam insulation roll is moisture resistant, fire-resistant, and has good strength to resist deformation with the closed-cell structure.
Low Thermal Conductivity

Reduces heat transfer effectively to optimize energy efficiency.

Acoustic Insulation

Substantially decreases noise pollution and sound transmission.

Fire & Moisture Resistant

Highly flame retardant and impervious to water vapor absorption.

Insulation Application 1
Insulation Application 2
Insulation Application 3
Insulation Processing 1
Insulation Processing 2
Insulation Processing 3
Insulation Close Up
Dimension Specifications
Thickness Width 1m Width 1.2m Width 1.5m
Inches mm Size (L*W) ㎡/Roll Size (L*W) ㎡/Roll Size (L*W) ㎡/Roll
1/4" 6 30 × 1 30 30 × 1.2 36 30 × 1.5 45
3/8" 10 20 × 1 20 20 × 1.2 24 20 × 1.5 30
1/2" 13 15 × 1 15 15 × 1.2 18 15 × 1.5 22.5
3/4" 19 10 × 1 10 10 × 1.2 12 10 × 1.5 15
1" 25 8 × 1 8 8 × 1.2 9.6 8 × 1.5 12
1 1/4" 32 6 × 1 6 6 × 1.2 7.2 6 × 1.5 9
1 1/2" 40 5 × 1 5 5 × 1.2 6 5 × 1.5 7.5
2" 50 4 × 1 4 4 × 1.2 4.8 4 × 1.5 6
Dimension Visual 1
Dimension Visual 2
Technical Data
Property Unit Value Test Method
Temperature range °C (-50 - 110) GB/T 17794-1999
Density range Kg/m³ 45-65Kg/m³ ASTM D1667
Water vapor permeability Kg/(m.s.pa) ≤0.91×10 ﹣¹³ DIN 52 615 / BS 4370 Part 2 1973
μ - ≥10000 -
Thermal Conductivity W/(m.k) ≤0.030 (-20°C) ASTM C 518
≤0.032 (0°C)
≤0.036 (40°C)
Fire Rating - Class 0 & Class 1 BS 476 Part 6 part 7
Flame Spread and Smoke Developed Index - 25/50 ASTM E 84
Oxygen Index - ≥36 GB/T 2406, ISO4589
Water Absorption, % by Volume % 20% ASTM C 209
Dimension Stability - ≤5 ASTM C534
Fungi resistance - Good ASTM G21
Ozone resistance Good GB/T 7762-1987
Resistance to U.V. and weather Good ASTM G23

Closed cell foam coated with aluminum foil, high closed cell ratio, significantly improve the water vapor isolation ability, not easy to condensation, moisture resistance is excellent, to ensure the insulation effect.

Frequently Asked Questions
What are the key benefits of using aluminum foil-clad rubber foam insulation?
It provides excellent thermal insulation with low thermal conductivity, high moisture resistance due to its closed-cell structure, superior fire performance (Class 0 & Class 1), and effectively minimizes sound transmission.
How does the aluminum foil cladding improve performance?
The aluminum foil coating acts as a highly protective vapor barrier. It significantly enhances water vapor isolation, prevents condensation, and provides added physical strength to resist surface deformation and weathering.
What is the working temperature range for this insulation roll?
This insulation roll can operate safely and maintain performance over a wide temperature range, specifically from -50°C to 110°C, according to the GB/T 17794-1999 test standard.
Is this insulation roll fire-resistant?
Yes, it has excellent fire performance, achieving Class 0 & Class 1 fire ratings according to BS 476 Part 6 & Part 7 standards, and a Flame Spread/Smoke Developed Index of 25/50 according to ASTM E 84.
Does the material resist mold and environmental degradation?
Yes, technical data shows good resistance against fungi (ASTM G21), ozone (GB/T 7762-1987), as well as robust resistance to U.V. radiation and weathering (ASTM G23).
What dimensions and thicknesses are available?
Thicknesses range from 1/4" (6mm) up to 2" (50mm). Roll widths are available in standard 1m, 1.2m, and 1.5m configurations, with variable lengths from 4m up to 30m depending on the selected thickness.