Kingflex Kingflex

China Kingflex insulation tube excellent performance meets different applications Pricelist, Quotes

Kingflex insulation tube excellent performance meets different applications. With nitrile rubber as the main raw material, it is foamed into a flexible rubber-plastic heat-insulating material with completely closed bubbles. The excellent product performance makes the product widely used in various public places, industrial plants, clean rooms and medical education institutions. Normal wall thicknesses of 1/4”, 3/8″, 1/2″, 3/4″,1″, 1-1/4”, 1-1/2″ and 2” (6, 9, 13, 19, 25 , 32, 40 and 50mm). Standard Length with 6ft (1.83m) or 6.2ft(2m).

Product Description

Thermal Insulation Application
Flexible Rubber Insulation Roll
Acoustic Insulation Detail
Elastomeric Insulation Foam
Improve the energy efficiency of the building
Reduce transmission of exterior sound to the interior of the building
Absorb reverberating sounds within the building
Provide thermal efficiency
Keep the building warmer in winter and cooler in summer
Excellent thermal insulation - very low thermal conductivity
Excellent acoustic insulation - can reduce noise and sound transmitting
Moisture resistant, fire resistant
Good strength to resist deformation
Closed Cell Rubber Structure

With nitrile rubber as the main raw material, it is foamed into a flexible rubber-plastic heat-insulating material with completely closed bubbles, which makes the product widely used in various public places, industrial plants, clean rooms and medical education institutions.

Insulation Manufacturing
Insulation Testing
Rubber Foam Sheet
Elastomeric Sheet Insulation
Insulated Pipes
Quality Control
Warehouse Storage
Technical Data
Property Unit Value Test Method
Temperature range °C (-50 - 110) GB/T 17794-1999
Density range Kg/m³ 45-65Kg/m³ ASTM D1667
Water vapor permeability Kg/(m.s.pa) ≤0.91×10 ﹣¹³ DIN 52 615
BS 4370 Part 2 1973
μ - ≥10000 -
Thermal Conductivity W/(m.k) ≤0.030 (-20°C) ASTM C 518
≤0.032 (0°C)
≤0.036 (40°C)
Fire Rating - Class 0 & Class 1 BS 476 Part 6 part 7
Flame Spread and Smoke Developed Index - 25/50 ASTM E 84
Oxygen Index - ≥36 GB/T 2406, ISO4589
Water Absorption, % by Volume % 20% ASTM C 209
Dimension Stability - ≤5 ASTM C534
Fungi resistance - Good ASTM 21
Ozone resistance Good GB/T 7762-1987
Resistance to U.V. and weather Good ASTM G23

Frequently Asked Questions

QWhat is the main material of this insulation product?

The main raw material is nitrile rubber, which is foamed into a highly flexible rubber-plastic heat-insulating material featuring a completely closed bubble structure.

QWhat is the applicable temperature range for this insulation material?

This material is rated to perform safely and efficiently across a temperature range of -50°C to 110°C, tested in compliance with GB/T 17794-1999 standards.

QHow does the product perform in fire safety evaluations?

The material achieves a Class 0 & Class 1 Fire Rating according to BS 476 Part 6 & 7 standards. It also meets the ASTM E 84 standard with a Flame Spread and Smoke Developed Index of 25/50.

QIs this material resistant to moisture and environmental degradation?

Yes, it features a water vapor permeability of ≤0.91×10 ﹣¹³ Kg/(m.s.pa) and excellent resistance to fungi, ozone, ultraviolet (U.V.) light, and weathering.

QCan this material be used for acoustic noise reduction?

Yes, the closed-cell rubber structure provides excellent acoustic insulation, which effectively absorbs reverberating sounds and reduces sound transmission within buildings.