Kingflex
| Technical Data | |||
|---|---|---|---|
| Property | Unit | Value | Test Method |
| Temperature range | °C | (-50 - 110) | GB/T 17794-1999 |
| Density range | Kg/m³ | 45-65Kg/m³ | ASTM D1667 |
| Water vapor permeability | Kg/(m.s.pa) | ≤0.91×10 ﹣¹³ | DIN 52 615 / BS 4370 Part 2 1973 |
| μ (Water Vapor Diffusion Resistance) | - | ≥10000 | - |
| Thermal Conductivity | W/(m.k) | ≤0.030 (-20°C) | ASTM C 518 |
| ≤0.032 (0°C) | |||
| ≤0.036 (40°C) | |||
| Fire Rating | - | Class 0 & Class 1 | BS 476 Part 6 & Part 7 |
| Flame Spread and Smoke Developed Index | - | 25/50 | ASTM E 84 |
| Oxygen Index | - | ≥36 | GB/T 2406, ISO 4589 |
| Water Absorption, % by Volume | % | 20% | ASTM C 209 |
| Dimension Stability | - | ≤5 | ASTM C534 |
| Fungi resistance | - | Good | ASTM 21 |
| Ozone resistance | Good | GB/T 7762-1987 | |
| Resistance to U.V. and weather | Good | ASTM G23 | |
High synthetic rubber base characterized by a completely closed-cell configuration, ensuring outstanding thermal barrier performance.
Provides excellent insulation properties to minimize heat loss and prevent energy waste across standard pipelines and systems.
The outer surface is smooth and flat, offering a highly professional, clean look for exposed pipe installations and equipment.
Made of premium NBR and PVC. It contains no fibrous dust, benzaldehyde, or chlorofluorocarbons, delivering high environmental and safety standards.
Exhibits high resistance against UV rays, ozone, and harsh outdoor weather environments, extending service life.
Available in multiple dimensions to match specific project specifications and widely preferred for complex pipework or duct installations.
This insulation operates effectively within a temperature range of -50°C to 110°C, tested in compliance with standard GB/T 17794-1999.
It meets Class 0 & Class 1 fire ratings according to BS 476 Part 6 & Part 7, and passes the ASTM E 84 standard with a Flame Spread / Smoke Developed index of 25/50.
Yes. The closed-cell structure offers high water vapor permeability resistance (μ ≥ 10000) and limits water absorption by volume to 20% under ASTM C 209 testing.
No, the insulation tube is manufactured using NBR and PVC. It does not contain fibrous dust, benzaldehyde, or Chlorofluorocarbons (CFCs).
Yes, it features excellent resistance to ozone, UV radiation, and general weathering, tested in accordance with ASTM G23 and GB/T 7762-1987 standards.
They are widely applied for structural insulation in general pipework and ducting systems, offering high efficiency, sound decorative value, and energy conservation.