Kingflex
| Technical Data | |||
|---|---|---|---|
| Property | Unit | Value | Test Method |
| Temperature range | °C | (-50 - 110) | GB/T 17794-1999 |
| Density range | Kg/m³ | 45-65Kg/m³ | ASTM D1667 |
| Water vapor permeability | Kg/(m.s.pa) | ≤0.91×10 ﹣¹³ | DIN 52 615 / BS 4370 Part 2 1973 |
| μ | - | ≥10000 | - |
| Thermal Conductivity | W/(m.k) | ≤0.030 (-20°C) | ASTM C 518 |
| ≤0.032 (0°C) | |||
| ≤0.036 (40°C) | |||
| Fire Rating | - | Class 0 & Class 1 | BS 476 Part 6 part 7 |
| Flame Spread and Smoke Developed Index | - | 25/50 | ASTM E 84 |
| Oxygen Index | - | ≥36 | GB/T 2406, ISO4589 |
| Water Absorption, %by Volume | % | 20% | ASTM C 209 |
| Dimension Stability | - | ≤5 | ASTM C534 |
| Fungi resistance | - | Good | ASTM 21 |
| Ozone resistance | Good | GB/T 7762-1987 | |
| Resistance to U.V. and weather | Good | ASTM G23 | |
Closed-cell rubber foam insulation material is used for the insulation and insulation of the shells of large tanks and pipes in construction, commercial and industrial, the insulation of central air-conditioning ducts, the insulation of household air-conditioning joints and automotive air-conditioning.
24 hours on-line service to help you answer questions and solve problems with no concern.
🔹 What is the temperature range of the closed-cell rubber foam insulation?
The material is designed to operate efficiently within a temperature range of -50°C to 110°C, tested in compliance with GB/T 17794-1999 standards.
🔹 How does this material perform in terms of fire safety?
It features excellent fire performance, holding a Class 0 & Class 1 Fire Rating under BS 476 Part 6 & 7, and meets the 25/50 Flame Spread and Smoke Developed Index standards (ASTM E 84).
🔹 Where is this closed-cell rubber foam insulation typically applied?
It is widely used for insulating shells of large tanks and pipes in construction, commercial, and industrial facilities, central air-conditioning ducts, household air-conditioning joints, and automotive air-conditioning.
🔹 What is the thermal conductivity of this insulation material?
According to ASTM C 518 testing, the thermal conductivity values are ≤0.030 W/(m.k) at -20°C, ≤0.032 W/(m.k) at 0°C, and ≤0.036 W/(m.k) at 40°C.
🔹 Does the foam insulation provide protection against environmental factors?
Yes, it demonstrates good resistance to U.V. and weather (ASTM G23), ozone (GB/T 7762-1987), and fungi growth (ASTM 21), ensuring long-term durability in varied environments.
🔹 How does this product prevent condensation and save energy?
Thanks to its high water vapor resistance factor (μ ≥ 10000) and low permeability, it blocks moisture ingress, which effectively prevents condensation, frost formation, and thermal loss.