Wholesale Kingflex thermal insulation glue 520 Supplier, Pricelist

Color KingGlue 520: Light tan Net Weight Around 6.9 lb per gallon (830 g/l) Composition Synthetic rubber base with synthetic resins and fillers added; hydrocarbon and ketone-type solvents. Solids Content Approximately 23% by weight for KingGlue 520 Coverage 200 sq ft (5m2/l) per gallon max, single coat (depending upon porosity of materials bonded and air temperature) Shelf Life 1-1/2 years for KingGlue 520 under storage temperature60°F to 80°F (16°C to 27°C) Minimum Drying Time 3–5 minutes under normal conditions Temperature Limits 250 F(120°C)—Kingflex Pipe Insulation seams and joints 180°F (82°C)—full-bonding Kingflex Sheet Insulation Container Sizes Litre and gallon containers

Product Description

KingGlue 520 Adhesive is an air-drying contact adhesive that is excellent for joining seams and butt joints of Kingflex Pipe and Sheet Insulation for line temperatures up to 250°F (120°C). The adhesive may also be used to apply Kingflex Sheet Insulation to flat or curved metal surfaces that will operate at temperatures up to 180°F (82°C).

KingGlue 520 will make a resilient and heat-resistant bond with many materials where the use of a solvent-base neoprene contact adhesive is suitable and desirable.
Application Instructions
Mix well, and apply only to clean, dry, oil-free surfaces. For best results, the adhesive should be brush-applied in a thin, uniform coat to both bonding surfaces. Allow the adhesive to tack prior to joining both surfaces. Avoid open time of more than 10 minutes. KingGlue 520 Adhesive bonds instantly, so pieces must be positioned accurately as contact is made. Moderate pressure should then be applied to the entire bonding area to insure complete contact.
🌡️Temperature Guidelines
It is recommended that the adhesive be applied at temperatures above 40°F (4°C) and not on heated surfaces. Where application between 32°F and 40°F (0°C and 4°C) cannot be avoided, exercise more care in applying the adhesive and closing the joint. Applications below 32°F (0°C) are not recommended.
Curing for Hot Operations
Where lines and tanks that are insulated will operate at hot temperatures, KingGlue 520 Adhesive must cure a minimum of 36 hours at room temperature to attain heat resistance for insulated pipe to 250°F (120°C) and insulated tanks and equipment to 180°F (82°C).
Insulation Curing Times
Kingflex Pipe Insulation
Adhesive-bonded seams and joints of Kingflex Pipe Insulation must cure before finishes are applied. Where the insulation is installed by adhering seams and butt joints, the adhesive must cure 24 to 36 hours.
Kingflex Sheet Insulation
Adhesive-bonded seams and joints of Kingflex Sheet Insulation must cure before finishes are applied. Where the insulation is installed by adhering seams and butt joints only, the adhesive must cure 24 to 36 hours. Where the insulation is installed against surfaces with full adhesive coverage, requiring wet adhesive at joints, the adhesive must cure seven days.
⚠️Safety Precautions
Extremely flammable mixture; vapors may cause flash fire; vapors may ignite explosively; prevent buildup of vapors—open all windows and doors—use only with cross ventilation; keep away from heat, sparks, and open flame; do not smoke; extinguish all flames and pilot lights; and turn off stoves, heaters, electric motors, and other sources of ignition during use and until all vapors are gone; close container after use; avoid prolonged breathing of vapor and prolonged contact with skin; do not take internally; keep away from children.
Not for consumer use. Sold only for professional or industrial application.
Frequently Asked Questions
Q1: What are the main applications of KingGlue 520 Adhesive?
KingGlue 520 is an air-drying contact adhesive designed for joining seams and butt joints of pipe and sheet insulation. It can also apply sheet insulation to flat or curved metal surfaces.
Q2: What is the recommended temperature range for applying this adhesive?
It is best applied at temperatures above 40°F (4°C). If application between 32°F and 40°F (0°C and 4°C) is necessary, exercise extra care. Applications below 32°F (0°C) are not recommended.
Q3: How long does the adhesive need to cure for high-temperature operations?
For insulated lines and tanks operating at hot temperatures, the adhesive must cure for a minimum of 36 hours at room temperature to ensure heat resistance.
Q4: What is the curing time for sheet insulation with full coverage application?
When sheet insulation is installed against surfaces with full adhesive coverage requiring wet adhesive at joints, the adhesive must cure for seven days before finishes are applied.
Q5: Can consumers purchase and use KingGlue 520 Adhesive?
No, this product is not intended for consumer use. It is sold exclusively for professional or industrial applications due to safety requirements.
Q6: What safety measures should be followed during application?
Since the mixture is extremely flammable, ensure proper cross-ventilation, keep it away from heat, sparks, open flames, and electrical ignition sources. Avoid breathing vapors or skin contact.

Related Products